For the time-dependent control of temperatures in closed rooms. Suited for all kinds of heating systems. Valve: normally closed type. The device can also be used as the main controller that enables to trigger the temperature decrease operations of other controllers
Technical Data | |
Operating Voltage: | 230 v ~, 50 Hz |
Sensor: | NTC, internal |
Switching Capacity: | 8 (2) A/230 V ~ |
Switching Contact: | Relay/make contact |
Setting Ranges: | 5…30°C (scale in °C) |
Switching Difference: | < 1 K |
Temperature Decrease: | Adjustable 5…29°C
(factory setting 17°C) |
Degree of Protection: | IP 30 |
Protection Class: | II, after installation
At 24 V ~ protection class III |
General Equipment: | Mechanical range reduction,
Summer-/wintertime changeover Child protection/valve protection |
Indications: | Symbol display with 9 function
Keys/°C or °F (Fahrenheit) |
Power Reserve: | Approx. 4 days |
Admissible Air Moisture: | Max. 95% r.h., non-condensing |
Storage Temperature: | -20…+70°C |
Safety and EMC: | Acc. to DIN EN 6073. |
Ambient Temperature: | 0…30°C |
Housing Colour: | Pure white, similar to RAL 9010 |
Housing Material: | Plastic (ABS) |